- Intended applications: Plug-pack switchmode DC power supply.
- Classification: Class II, safety isolating short circuit proof.
- Protection: Primary thermal fuse fitted.
- Construction: Wall mounting plug-pack, ABS plastic IP40
- Input: NZ / AU standard mains power point connecting.
- Output: Interchangable ELV plugs including ID 1.3 * OD 3.5mm, ID 1.5 * OD 5.9mm, ID 2.1 * OD 5mm, ID 2.1 * OD 5.5mm, ID 2.5 * OD 5mm. (configerable for center +ve or -ve)
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 60950.
- Dimensions: h. 60mm, w. 95mm, d. 60mm, 0.6kg
-
-
- Intended applications: Plug-pack switchmode DC power supply.
- Classification: Class II, safety isolating short circuit proof.
- Protection: Primary thermal fuse fitted.
- Construction: Wall mounting plug-pack, ABS plastic IP40
- Input: NZ / AU standard mains power point connecting.
- Output: Interchangable ELV plugs including ID 1.3 * OD 3.5mm, ID 1.5 * OD 5.9mm, ID 2.1 * OD 5mm, ID 2.1 * OD 5.5mm, ID 2.5 * OD 5mm. (configerable for center +ve or -ve)
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 60950.
- Dimensions: h. 40mm, w. 80mm, d. 40mm, 0.3kg
-
- Intended applications: In-line appliance transformers.
- Classification: Class 1, isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting & incorporated IEC appliance inlet fuse fitted T 10A (slow blow).
- Construction: Desk top in-line power supply, metal case epoxy powder coated IP40.
- Input: NZ / AU standard IEC mains cord-set.
- Output: Single NZ / AU style 3 pin socket outlet.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
- Dimensions: h. 220mm, w. 160mm, d. 300mm, 27kg
-
- Intended applications: In-line appliance transformers.
- Classification: Class 1, isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting & incorporated IEC appliance inlet fuse fitted T 10A (slow blow).
- Construction: Desk top in-line power supply, metal case epoxy powder coated IP40.
- Input: NZ / AU standard IEC mains cord-set.
- Output: Single NZ / AU style 3 pin socket outlet.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
- Dimensions: h. 220mm, w. 130mm, d. 300mm, 25kg
-
- Intended applications: In-line appliance transformers.
- Classification: Class 1, isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting & incorporated IEC appliance inlet fuse fitted T 10A (slow blow).
- Construction: Desk top in-line power supply, metal case epoxy powder coated IP40.
- Input: NZ / AU standard IEC mains cord-set.
- Output: Single NZ / AU style 3 pin socket outlet.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
- Dimensions: h. 220mm, w. 130mm, d. 300mm, 18kg
-
- Intended applications: In-line appliance transformers.
- Classification: Class 1, isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting & incorporated IEC appliance inlet fuse fitted T 5.0A (slow blow).
- Construction: Desk top in-line power supply, metal case epoxy powder coated IP40.
- Input: NZ / AU standard IEC mains cord-set.
- Output: Single NZ / AU style 3 pin socket outlet..
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
- Dimensions: h. 150mm, w. 100mm, d. 240mm, 11kg
-
- Intended applications: In-line appliance transformers.
- Classification: Class 1, isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting & incorporated IEC appliance inlet fuse fitted T 5.0A (slow blow).
- Construction: Desk top in-line power supply, metal case epoxy powder coated IP40.
- Input: NZ / AU standard IEC mains cord-set.
- Output: Single NZ / AU style 3 pin socket outlet.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
- Dimensions: h. 105mm, w. 100mm, d. 170mm, 6kg
-
- Intended applications: In-line appliance transformers.
- Classification: Class 1, isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting & incorporated IEC appliance inlet fuse fitted T 10A (slow blow).
- Construction: Desk top in-line power supply, metal case epoxy powder coated IP40.
- Input: NZ / AU standard IEC mains cord-set.
- Output: Single "North American" style 3 pin socket outlet.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
- Dimensions: h. 220mm, w. 130mm, d. 300mm, 25kg
-
- Intended applications: In-line appliance transformers.
- Classification: Class 1, isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting & incorporated IEC appliance inlet fuse fitted T 10A (slow blow).
- Construction: Desk top in-line power supply, metal case epoxy powder coated IP40.
- Input: NZ / AU standard IEC mains cord-set.
- Output: Single "North American" style 3 pin socket outlet.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
- Dimensions: h. 220mm, w. 130mm, d. 300mm, 18kg
-
- Intended applications: In-line appliance transformers.
- Classification: Class 1, isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting & incorporated IEC appliance inlet fuse fitted T 5.0A (slow blow).
- Construction: Desk top in-line power supply, metal case epoxy powder coated IP40.
- Input: NZ / AU standard IEC mains cord-set.
- Output: Single "North American" style 3 pin socket outlet.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
- Dimensions: h. 150mm, w. 100mm, d. 240mm, 11kg
-
- Intended applications: In-line 110~120vac appliance transformers.
- Classification: Class 1, isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting & incorporated IEC appliance inlet fuse fitted T 5.0A (slow blow).
- Construction: Desk top in-line power supply, metal case epoxy powder coated IP40.
- Input: NZ / AU standard IEC mains cord-set.
- Output: Single "North American" style 3 pin socket outlet.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.4 (IEC 61558.2.4).
- Dimensions: h. 105mm, w. 100mm, d. 170mm, 6kg
-
- Intended applications: In-line appliance transformers.
- Classification: Class 1, safety isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting.
- Construction: Desk top in-line power supply, ABS plastic IP40.
- Input: NZ / AU standard mains power point connecting.
- Output: Flying lead, 1.8 meter with stripped ends.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
- Dimensions: h. 75mm, w. 95mm, d. 205mm, 2.5kg
-
- Intended applications: In-line appliance transformers.
- Classification: Class 1, safety isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting.
- Construction: Desk top in-line power supply, ABS plastic IP40.
- Input: NZ / AU standard mains power point connecting.
- Output: Flying lead, 1.8 meter with stripped ends.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
- Dimensions: h. 75mm, w. 95mm, d. 205mm, 1.3kg
-
- Intended applications: In-line appliance transformers.
- Classification: Class 1, safety isolating short circuit proof.
- Protection: Primary thermal trip, self-resetting.
- Construction: Desk top in-line power supply, ABS plastic IP40.
- Input: NZ / AU standard mains power point connecting.
- Output: Flying lead, 1.8 meter with stripped ends.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
- Dimensions: h. 75mm, w. 95mm, d. 205mm, 1.0kg
-
- Intended applications: Plug-pack appliance transformers.
- Classification: Class II, safety isolating short circuit proof.
- Protection: Primary thermal fuse fitted.
- Construction: Wall mounting plug-pack, ABS plastic IP40.
- Input: NZ / AU standard mains power point connecting.
- Output: Flying lead with stripped ends (1.8 meter)
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
- Dimensions: h. 60mm, w. 75mm, d. 55mm, 0.4kg
-
- Intended applications: Plug-pack appliance transformers.
- Classification: Class II, safety isolating short circuit proof.
- Protection: Primary thermal fuse fitted.
- Construction: Wall mounting plug-pack, ABS plastic IP40
- Input: NZ / AU standard mains power point connecting.
- Output: Interchangable ELV plugs including ID 1.3 * OD 3.5mm, ID 1.5 * OD 5.9mm, ID 2.1 * OD 5mm, ID 2.1 * OD 5.5mm, ID 2.5 * OD 5mm.
- Operating conditions: 47~63Hz, rated ambient temp 30 deg C.
- Manufactured standard: ASNZS 61558.2.6 (IEC 61558.2.6).
- Dimensions: h. 60mm, w. 75mm, d. 55mm, 0.3kg